27
NOTE: If the First Digit entered is ‘1’, it must be entered as ‘01’. A = 10; B = 11; C = 12; D = 13; E = 14; F = 15
System Attribute Table
Delay Before Dial 0 to 255 seconds
Fire Delay Before Dial 0 to 255 seconds
AC Trouble Delay 0 to 255 minutes
Senior Watch Time 0 - 42 hours
System Attributes 00 to FF
(see the System
Attribute Table.)
Passcode Entry Lockout 0 = No Lock,
1 to 15 attempts
AC Cycles 0 = 60 Hz
1 = 50 Hz
Time in seconds that a user has after a Burglar, Holdup or Auxiliary Alarm from a zone
has occurred to silence the alarm with a disarm and abort the alarm event. (See
Section 3.3, Programming Note 12.)
Time in seconds that a user has after a Fire Alarm from a zone has occurred to silence
the alarm and abort the alarm event. (See Section 3.3, Programming Note 13.)
Time in minutes that AC power must be down until the condition is reported to the
Central Station. If time set is an odd number, it will be silent, if time set is an even
number, it will be audible at the keypad.
Time in hours during which there is no activity before a Senior Watch event is logged to
be reported. (See Section 3.3, Programming Note 10.)
Fire Bell (Steady/Temporal) - determines the operation of the Bell Output during a Fire
alarm.
Burglar Bell (Steady/Pulsed) - determines the operation of the Bell Output during a
Burglar alarm.
Holdup Bell (Steady/Pulsed) - determines the operation of the Bell Output during a
Holdup alarm.
Auxiliary Bell (Steady/Pulsed) - determines the operation of the Bell Output during an
Auxiliary alarm.
Log Alarm Abort Events - if enabled, Abort Alarm events are posted in the Event Log.
(See Section 3.3, Programming Notes 12 & 13.)
Log Access Events - if enabled, the “Keypad Access Activated” events will be posted in
the Event Log. These events are not reportable to the Central Station.
Print Access Only R/T - if enabled with a printer connected, then only Keypad Access
Activated” events will be printed. This does not affect the Event Log print command.
Bell Test on Arm - if enabled, then the Bell Output(s) for an area will be activated for
two seconds when that area is armed in the AWAY mode.
Sets the number of failed passcode entry attempts allowed before a 50 second lockout
for a particular Control Station.
Synchronizes the internal clock with the local power company’s 50 or 60 Hz for
accurate time keeping.
NOTE
Alarm Bell operations only affect the Bell Output. They do not affect the associated Alarm Indicator outputs.
Enter For: 0123456789ABCDEF
First Digit
All Features Below Disabled *
Log Alarm Abort Events ********
Log Access Events * * * * * * * *
Print Access Only R/T **** ****
Bell Test on Arm ********
Second Digit
Burglar Bell Steady * * * * * * * *
Burglar Bell Pulsed * * * * * * * *
Holdup Bell Steady **** ****
Holdup Bell Pulsed **** ****
Aux Bell Steady ********
Aux Bell Pulsed ********
Fire Bell Steady ********
Fire Bell Temporal ********
WWW.DIYALARMFORUM.COM